STWD9528 is a single component aromatic modified polyurea waterproof anti-corrosion protective coating. This product has good adhesion to concrete and steel substrates, and it is easy to apply without the need of specialized polyurea coating spraying equipment. Due to its unique chemical structure, the film-forming coating has good resistance to chemical medium and excellent waterproof performance, making it an ideal material for waterproof and anti-corrosion protection applications. The characteristics of high elasticity and high adhesion are particularly suitable for the waterproofing of building roofs, balconies, bathrooms, exterior walls, and basements, especially for the repair of old SBS membrane material roofs and the anti-corrosion and waterproofing of old colored steel tile roofs.
Features and benefits
*High solid content, low VOC emissions
*The application method is simple and does not require professional polyurea coating spraying equipment. It can be applied by brush, roller, or high-pressure airless machine.
*The coating has good flexibility, strong leakage resistance, and excellent waterproof performance.
*Excellent resistance to chemical medium corrosion, capable of withstanding certain concentrations of acids, alkalis, salts, oils, organic solvents, etc
*Excellent adhesion, which can quickly and firmly bond to the surface of substrates such as concrete, steel, wood, glass fiber, etc
*Wide temperature range for use ranging from -50 ºC to 120 ºC
*It is one component material, easy to apply, without the need for mixing, reducing labor costs
Application scope
Construction, water conservancy, transportation, chemical industry, electricity, etc. For example, waterproofing of building roofs, bathrooms, exterior walls, basements, water conservancy dams, hydropower station buildings, etc. Especially for the repair of old SBS membrane material roofs and the anti-corrosion waterproofing of old colored steel tile roofs coating.
Product information
Item | Results |
Appearance | Color is adjustable |
Specific gravity (g/cm3)) | 1.25±0.05 |
Viscosity (cps )@20ºC | 7500±500 |
Solid content (%) | ≥80 |
surface dry time (hrs) | 2-4 |
Pot life (hrs) | 1h |
theoretical coverage | 0.75kg/m2(thickness 500um) |
Item | Test standard | results |
Hardness (Shore A) | ASTM D-2240 | 78 |
Elongation (%) | ASTM D-412 | 420 |
tensile strength (Mpa) | ASTM D-412 | 16 |
Tear strength (kN/m) | ASTM D-624 | 62 |
abrasion resistance(750g/500r),mg | HG/T 3831-2006 | 10 |
Adhesive strength (Mpa) steel base | HG/T 3831-2006 | 8 |
Adhesive strength (Mpa) concrete base | HG/T 3831-2006 | 3.3 |
impact resistance (kg.m) | GB/T23446-2009 | 1.0 |
Density (g/cm3) | GB/T 6750-2007 | 1.25 |
Acid resistance 10%H2SO4 or10%HCl,30d | no rust, no bubbles, no peel off |
Alkali resistance 10%NaOH, 30d | no rust, no bubbles, no peel off |
Salt resistance 10g/L,30d | no rust, no bubbles, no peel off |
Salt spray resistance, 2000h | no rust, no bubbles, no peel off |
Oil resistance | no bubbles, no peel off |
0# d iesel, cru de oil, 30d | no rust, no bubbles, no peel off |
(For reference: pay attention to the influence of ventilation, splash and spillage. Independent immersion testing is recommended if requiring detail data.) |
Substrate temperature | Surface dry time | Foot traffic time | Solid cure |
+10ºC | 5h | 24h | 7d |
+20ºC | 3h | 16h | 6d |
+30ºC | 2h | 8h | 5d |
Shelf life
* Package: 5kg/barrel, 25kg/barrel.
* shelf life: 6 months (sealed)
* Storage environment temperature: 5 ºC -35 ºC
* store in cool and ventilated place, avoid sunshine direct exposure, keep away from heat.
coating Product health and safety information
For information and advice on the safe handling, storage and disposal of chemical coating products, users shall refer to the most recent Material Safety Data Sheet containing physical, ecological, toxicological and other safety related data.
Integrity declaration
SWD guarantee all technical data stated in this sheet are based on laboratory tests. Actual testing methods may vary due to different circumstances. Therefore please test and verify its applicability. SWD does not take any other responsibilities except the coating product quality and reserve the right of any modifications on the listed data without prior notice.